CAD nears clinical significance in pulmonary emboli

H. A. Abella
March 10, 2008

Computer-aided detection may lend an extra punch to the diagnosis of pulmonary embolism with multislice and dual-energy CT scanners. Studies by French and German researchers have shown it helps detect small, hard-to-spot clots lodged in the lungs' periphery.

Multislice CT angiography has become the diagnostic standard in pulmonary embolism, with a well-established accuracy in the detection of proximal lesions. But CTA detection of peripheral PE remains challenging and time-consuming, and it may lead to false positives. Can CAD pick those small clots missed by the radiologist's naked eye in the first read? Yes, it can, said principal investigator of a study from France Dr. Marion Dewailly from the University of Lille.

Dewailly and colleagues enrolled 74 patients who underwent diagnosis of peripheral acute PE with dual-source CTA and a CAD software (PECAD 7, Siemens). Two radiologists interpreted high- and low-quality angiograms done under varied conditions, including ECG-gated and nongated scanning.

The investigators found neither the scanning conditions nor the overall image quality influenced CAD results, which proved sensitive for detection of peripheral PE. Dewailly released her group's results Saturday in Vienna.

CAD detected 80 of 93 peripheral clots found in 21 patients. CAD's sensitivity for peripheral, segmental, and subsegmental clots was 86%, 78.3%, and 93.3%, respectively. Researchers found a mean number of 6.4 false positives per patient, mainly linked to hilar lymph nodes and perivascular airspace consolidation. The sensitivity for CAD was 84% for ECG-gated scans, 82% for dual-energy scans, and 76% for nongated scans. The difference was not statistically significant.

"CAD can complement the visual assessment of pulmonary clots by the radiologist. And dual energy can help with automatic detection of peripheral clots and identification of perfusion defects," she said.

In a study from Germany, researchers at sites in Nordhausen, Neustadt, and Jena compared CAD's performance against that of radiologists. They performed 160 CT examinations on patients suspected with PE and evaluated whether highlighted lesions were true or false positives.

The researchers found that CAD allows a better analysis of peripheral PE and that most false-positive markers highlight perivascular soft tissue. They also found an association between the total number of CAD markers per case and D-dimer results, which bore diagnostic and prognostic connotations.

CAD proves to be a useful tool to differentiate peri- and intravascular tissue and to diagnose mainly peripherally located emboli, according to principal investigator and presenter Dr. Ansgar Malich.

"We use that tool as a second reader," Malich said.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Article Tools

What's New on DiagnosticImaging.com

So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy