DiagnosticImaging Members: Login | Register
Diagnostic Imaging Recommended Medical Sites Medline Drugs

Powered by SearchMedica

 
  • Home
  • Blog
  • Conference Reports
  • Case Studies
  • Jobs
  • Product Directory
  • Voice Recognition
  • Low Dose
  • RSNA 2011
  • PET-MR

Home » Conference Reports » ISMRM 2007

NewsfromISMRM2007

ISMRM 2007


View slide show

ISMRM2007


 

MR imaging of knee at 7T overcomes limitations of 1.5T exams

Philip Ward
May 25, 2007

German researchers have developed a protocol for MRI of the knee at 7T that reportedly allows visualization of all relevant anatomical structures and the most common pathologies.

Accurate diagnoses of the musculoskeletal system are important because diseases of the joints cause a high morbidity in both older and younger patients. MRI at a field strength of 1.5T has its limits, especially in small structures like articular cartilage, and 7T systems can provide increased signal-to-noise ratio and higher spatial resolution, according to Dr. Oliver Kraff with the Erwin L. Hahn Institute for MRI at Duisburg-Essen University, Essen.

"Measurement protocols optimized for MRI at field strengths of 1.5T and 3T cannot be directly transferred to 7T," he told ISMRM-ESMRMB delegates. "Specific absorption rate limitations, different relaxation times of the tissues, and new image artifacts (e.g., due to enhanced susceptibility effects) require adjustments of the sequence parameters."

All measurements at Essen were performed on a Magnetom 7T whole-body system from Siemens Medical Solutions, using a CP knee coil from Invivo for transmit and receive. Starting with sequences used in a 1.5T knee protocol, the parameters were modified to obtain optimal image contrast, full coverage, and the highest resolution within a reasonable acquisition time. The knee protocol was first optimized on two healthy volunteers and subsequently tested on 10 patients with pathologies.

For the STIR sequence, an inversion time of 250 msec was needed for optimal fat suppression at 7T. TE was set to 33 msec because a higher TE would have created more prominent susceptibility artifacts. A T1-weighted 3D FLASH data set covering the entire extremity yielded very high spatial resolution for a good anatomic overview, Kraff said.

The specific absorption rate (SAR) becomes a major issue in double-echo TSE sequences due to the large flip angle of 150º, resulting in a limit of only a few slices per acquisition. Choosing a low SAR RF PULSE leads to an improved outcome without reducing image quality. Several measurements are necessary for complete coverage. Gradient echo sequences, particularly MEDIC, seem particularly suitable for assessment of cartilage pathologies, and a DESS sequence has been tested to display cartilage lesions.

The protocol rendered excellent image quality at 7T, and enabled better visualization of meniscal tears and cruciate ligaments.

"The contrast between the lesion and the normal cartilage is higher at 7T compared with 1.5T," he said. "Also, DESS and double-echo TSE render good contrast and high resolution for assessing cartilage degeneration."

Using this protocol, the total data acquisition for the whole knee is about 45 minutes. No improvement was observed for osseous lesions using the STIR sequence.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Videos

Integration Relation: Jacques Coumans, VP of MR Marketing, Philips Medical Systems

Integration Relation: Jacques Coumans, VP of MR Marketing, Philips Medical Systems

Integration Relation: Jacques Coumans, vice president of MR marketing for Philips Medical Systems, explains how the company's acquisition last year of Intermagnetics, along with its subsidiary, Invivo, has simplified functional MR and how Philips' efforts to do so relate to its corporate policy of making sophisticated MR techniques easier to do. DI business editor Greg Freiherr has the report.
View video

 


MR Robot: Prof. Dr. Andreas Melzer, Co-Founder of InnoMedic

MR Robot: Prof. Dr. Andreas Melzer, Co-Founder of InnoMedic

MR Robot: Prof. Dr. Andreas Melzer, director of the Institute for Medical Sciences and Technology at the University of Dundee in Scotland and co-founder of InnoMedic, describes at the ISMRM meeting a robot designed for MR interventions. The device, now in clinical testing, takes cues from an MR scan to position a probe at an exact point and along a specific trajectory. DI business editor Greg Freiherr has the report.
View video

What'sNewonDiagnosticImaging


So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012


CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy