RSNA 2005


Click Here to view slide show


 

CAD falls short in breast cancer screening

Emily Hayes
December 2, 2005

When it comes to spotting suspicious lesions on a screening mammogram, computer-aided detection is no match for a dedicated breast imaging specialist, according a large study by researchers at Yale, presented Thursday at the RSNA meeting.

Researchers conducted a prospective study of 5875 consecutive screening mammograms performed at Yale's Breast Imaging Center between February and September 2005. Two-thirds of the studies were performed on conventional film-based systems and one-third on digital equipment.

Researchers at Yale's dedicated breast imaging facility have found poor correlation between CAD markings and interpretations by dedicated breast imagers.

FIGURE 1. Spiculated mass not prompted by CAD was found to be infiltrating ductal carcinoma. FIGURE 2. Calcifications not prompted by CAD were determined to be DCIS. (Provided by L. Bryan-Rest)

The study compared CAD markings with interpretation by the facility's radiologists, whose experience in breast imaging ranged from four to 20 years. Researchers looked at the correlation overall and compared characterization masses, calcifications, density, and architectural distortion. They also reviewed follow-up diagnostic mammograms, but these were not available in all cases.

Of the total screened, radiologists' interpretations indicated there were 735 actionable lesions in 637 patients. CAD markings correlated with these interpretations in just 48% of lesions.

"There is poor correlation between CAD and actionable findings. These findings erode confidence in CAD," said Dr. Lara Bryan-Rest, who presented the study findings. "Complete reliance on CAD by non-experts is strongly discouraged," she added.

The level of correlation varied depending on the type of lesion. CAD markings correlated with radiologist interpretation in 65% of calcification cases but only 43% of masses.

"CAD was better with calcifications," Bryan-Rest said.

The Yale study adds to a conflicting body of evidence about the value of CAD. A large prospective study of 12,000 mammograms published in 2001 showed a benefit of 20% for breast cancer detection. Conversely, a large retrospective study of 115,000 screening mammograms published in 2004 showed little benefit.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





What'sNewonDiagnosticImaging.com


So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012

Sponsor




Riverain Medical
RapidScreen®
Chest Radiography CAD
Booth #3945 South Hall

RapidScreen® – the only FDA-approved-for-marketing chest radiography CAD system – transforms your most prevalent imaging procedure into the ultimate first line of defense against lung cancer, helping radiologists detect up to 20% more early stage lung cancers.

www.riverainmedical.com




Standards can hang you
Bradley M. Tipler, M.D.
Monday the convention seemed like old times. Apparently, most U.S. radiologists waited until Sunday to come to the meeting, as I saw far more recognizable faces the second day. I guess they like leftover turkey more than I do.
December 01, 2005

Staff


Meet Our Staff

CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy