Five lung nodule measuring programs show little variation

C. P. Kaiser
November 29, 2007

Nearly all lung nodules were segmented successfully with a point-and-click approach from four out of five vendor programs. Even with this approach, however, intraobserver 3D volumetric measurement agreement was close to but not 100% repeatable.

"This finding should be considered in the clinical application and interpretation of nodule volume measurement," said Dr. Cheng Tao, a radiologist at the University of Pittsburgh.

Tao and colleagues from Pittsburgh and Washington University in St. Louis selected 89 nodules from 56 randomly selected subjects enrolled in the National Lung Screening Trial.

Nodules were segmented and measured for their 3D volumes by point-and-clicking over them using semi-automated programs from GE Healthcare, MeVis, Philips Medical Systems, Siemens Medical Solutions, and Vital Images. Vendors were anonymized for the study and identified as A, B, C, D, and E.

Researchers repeated the measurements at one-week intervals. Two programs (A and B) allowed them to manually adjust automatically segmented nodule boundaries and revise volume measurements.

While the success rate of point-and-click nodule segmentation varied among the vendors, all but one achieved between 95% and 100%. The success rate for program C was 86.5%. Some nodules were segmented clearly erroneously (mostly in C) or failed to be segmented (mostly in B).

The same group, this time led by Dr. Kyongtae Bae, found that nodule volume measurement by the point-and-click approach without appropriate adjustment may result in considerable differences in volume measurements depending on the program used.

Researchers compared the 3D volume measurements of all five vendors, plus the adjusted volumes of A (Aa) and B (Ba). Senior author Dr. David Gierada presented the results on Wednesday.

Comparison of all measurements revealed that vendor A had significant differences with all other measurements except Aa. The boundary adjustment affected volume differently on A and B (i.e., Aa was greater than A, but Ba was smaller than B).

Overall, A to E measurements were strongly correlated (r = 0.79 to 0.99). While B was the least well correlated (r = 0.79 to 0.93), Ba tended to have the highest correlations (r = 0.88 to 0.99), indicating considerably reduced differences with the adjustment, Tao said.

A third study from the same group evaluated the ability of LungCARE, a computer-aided program from Siemens, to automatically match pulmonary nodules in serial CT scans. Tao reported a successful matching rate of 92.5%.

Researchers randomly selected 40 subjects enrolled in the NLST with pulmonary nodules depicted in three-year serial studies (T0, T1, T2). The number of nodules that were detected and documented by radiologists who initially interpreted the screening CT was 108 (T0), 104 (T1), and 101 (T2).

Two radiologists used LungCARE to evaluated the matched detection of T0 nodules onto T1 nodules, and T1 nodules onto T2 nodules. The matching rates, type (isolated, juxtavascular, juxtapleural, and ground-glass), and size (≤4 mm, >4 to 6 mm, >6 to 8 mm, >8 mm) of nodules were recorded.

The overall matching rate of the documented nodules was 92.5%. By nodule type, it was 96.4% (isolated), 100% (juxtavascular), 84.2% (juxtapleural), and 100% (ground-glass).

By nodule size, the matching rate was 92.4% (≤4 mm), 94.9% (>4 to 6 mm), 88.9% (>6 to 8 mm), and 81.8% (>8 mm).

"Automated matching of lung nodules between serial CTs is a promising technique to enhance the diagnostic performance in follow-up screening CT," Tao said, adding that the matching rate was lower with juxtapleural location.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Videos


Siemens puts the interventional into I Robot

Siemens puts the interventional into I Robot

An eight-foot robot arm spins, turns, and twists to demonstrate the unprecedented flexibility of an interventional system debuting at the Siemens Medical Solutions booth. Siemens exec Thomas Truesdell describes for Diagnostic Imaging's business editor Greg Freiherr how this work-in-progress Artis zeego can make interventions easier and more productive.
View video

 

What'sNewonDiagnosticImaging.com


Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012
PET Technique Useful in Challenging Breast Cancer Cases
February 7, 2012
Practices Adjust Workflow, IT for Tomosynthesis Adoption
February 7, 2012
Large Hospital System Successfully Adopts CPOE for Radiology
February 7, 2012



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy