Smaller FOV cuts dose but maintains sensitivity for detecting pulmonary emboli

James Brice
November 28, 2007

An abbreviated field-of-view can lead to a 48% cut in radiation dose for CT pulmonary embolism exams and 96% dose reduction compared to full-view 64-slice CT triple rule-out without affecting the diagnostic sensitivity of either procedure.

Dr. Hetal Patel, a radiologist with Hartford Hospital-Jefferson Radiology in Hartford, CT, presented results from a retrospective evaluation of 600 CTA exams for pulmonary emboli studies that demonstrated the value of condensing the FOV by eliminating areas above the aortic arch and below the heart.

Fifty (8.3%) of the studies were positive for PE, 534 (89%) were negative, and 16 (2.7%) were deemed suboptimal because of patient motion or poor arterial tree opacification, Patel said. Of those 50 positive CT pulmonary angiography scans (CTPA), no pulmonary embolus was seen only in the lungs above the arch and below the heart, the region excluded from the abbreviated-FOV exams.

The standard CTPA with beam modulation covered 330 mm longitudinally. It exposed patients to 5.4 mSv of radiation, compared to 186 mm of longitudinal coverage that generated 2.8 mSv of exposure, Patel said. A full-chest contrast triple rule-out exam involved 21.9 mSv, compared to the 12.7 mSv for the same procedure in a more limited FOV.

Patel also found that the coronary CTA approach adopted for the triple rule-out scan generated significantly more radiation than CT pulmonary angiography. The abbreviated FOV at least partially mitigates that higher radiation exposure.

"If the sole concern is pulmonary embolus detection, limiting the scan field from the top of the aortic arch to the bottom of the heart would lower the dose without lowering the exam's diagnostic sensitivity," Patel said.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Videos


Siemens puts the interventional into I Robot

Siemens puts the interventional into I Robot

An eight-foot robot arm spins, turns, and twists to demonstrate the unprecedented flexibility of an interventional system debuting at the Siemens Medical Solutions booth. Siemens exec Thomas Truesdell describes for Diagnostic Imaging's business editor Greg Freiherr how this work-in-progress Artis zeego can make interventions easier and more productive.
View video

 

What'sNewonDiagnosticImaging.com


So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy