Diagnostic Imaging. Vol. 30 No. 11
 

Toshiba sets 'dynamic volume' as new CT frontier

Aquilion One scanner covers 16 cm to allow whole-organ images with temporal uniformity

By Doug Ryan | November 1, 2008
Mr. Ryan is senior director of the CT business unit for Toshiba America Medical Systems.

Early CT systems delivered insights about the body’s anatomy that were previously impossible. The following generations of scanners provided new capabilities to cover more anatomical area and acquire volume data sets in a single short breath-hold, an evolution that leaped forward in the late 1990s with the introduction of the multirow detector. This gave clinicians the ability to acquire isotropic volumetric data using thin slices that could be viewed with equally high resolution in any plane.

Although this advanced form of CT has progressed rapidly since its introduction, even the newest such scanners are limited to 8 cm per gantry rotation and, therefore, still require helical scanning. Their limited coverage means the volumes acquired for whole-organ interpretation and perfusion studies are not temporally uniform, because each portion of the volume is acquired at different moments in time.

To overcome this clinical limitation, Toshiba designed a new generation of CT technology called dynamic volume CT. With our introduction of a wide area detector (320 rows x 0.5 mm covering 16 cm) onboard the Aquilion One, CT takes a significant leap beyond even the breakthroughs of the last 30 years, providing data sets of whole organs and orthopedic joints, and 4D data sets of complex motions that can be viewed over time. A simple example of this is the ability to acquire whole-brain perfusion studies that can be viewed over the precontrast, arterial, and venous phases. Beyond the enhanced clinical diagnosis that can be realized by a perfectly timed arteriogram and venogram, the data can also be displayed for the first time as a wholebrain CT digital subtraction angiography data set and a temporally uniform whole-brain perfusion study.

The capacity to display the data dynamically has created a significant advancement in the ability to diagnose patients in a noninterventional way. This technology makes a considerable impact on radiation dose as well by eliminating the need for helical scanning.

One of the greatest advantages of the Aquilion One dynamic volume CT is its potential to change clinical pathways and not only improve how patients are diagnosed, but also save the healthcare system money by eliminating duplicative tests. An example is the ability to get a complete neurological study in less than one minute with one contrast injection.

Using 320-detectorrow dynamic volume CT, the data necessary to evaluate a patient can be acquired with one study, using only 50 cc of contrast and 5 mSv of radiation dose. The use of dynamic volume CT for this patient is faster, safer, and more comprehensive and can be accomplished at a significantly lower cost to the healthcare system than any other imaging method. In covering 16 cm per gantry rotation, the Aquilion One can cover entire organs with a single low-dose acquisition. This opens up the possibility of visualizing dynamic motion and perfusion of anatomy in ways that has not previously been possible.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





RSNA 2008 Preview

RSNA Preview: Trials examine added value of advanced breast imaging strategies
November 25, 2008

Themes emerging from breast imaging abstracts at the upcoming RSNA include the increased use of breast MRI, full-field digital mammography versus film-screen mammography, and more.

RSNA preview: Focus sessions explore imaging controversies
November 20, 2008

You can tell by the titles of special focus sessions planned for the 2008 RSNA that program committee chair Dr. Robert M. Quencer sees an opportunity to use the sessions to examine tough issues affecting clinical imaging practice.

RSNA preview: CAD improves detection of pulmonary embolisms
November 20, 2008

Computer-aided detection significantly improves the sensitivity of pulmonary embolism imaging, according to a study that will be presented at the 2008 RSNA meeting. Other studies show that specially developed CAD schemes can detect flat lesions that are often missed in CT colonography.

RSNA preview: Cancer specialists voice mixed feelings about oncology imaging
November 20, 2008

RSNA presentations on prostate cancer staging and treatment, along with talks on radiation therapy for thoracic malignancies, have piqued the interest of cancer care specialists. But in general, oncologists and radiation oncologists conveyed some reservations about this year’s offerings in oncologic imaging and therapies.

RSNA preview: CT coronary angiography, CT colonography gain widespread use
November 20, 2008

Highlights of the 2008 RSNA meeting include discussions about the use of CT angiography as a noninvasive technique for diagnosing coronary artery disease and the replacement of standard optical colonoscopy with CT colonography to screen for colon cancer.

RSNA preview: Scientific sessions expand limits of imaging diagnosis and guidance
November 20, 2008

There is nothing like a little momentum to help the RSNA organizers present the latest developments in imaging research in the meeting’s scientific sessions. Everyone associated with imaging sciences from Beijing to New York City understands that presenting research in Chicago is an essential requirement for membership in this unique community.

RSNA preview: Musculoskeletal radiology evolves from anatomic to functional imaging
November 18, 2008

Highlights of the 2008 RSNA meeting suggest the field of musculoskeletal radiology is moving away from purely descriptive imaging studies and more into quantitative ones. Research is advancing the understanding of tissue function and underlying anomalies as well as image-guided treatment options.

Tech advisor CT vendors plot strategies for growth
November 1, 2008

CT vendors have diverged this year as never before, choosing technological paths to new generations of scanners that reflect their own particular engineering strengths and history of R&D. Core developments by each have translated into novel capabilities. Software and mechanical fixes have countered weaknesses.

Enterprise imaging unfolds as future direction of PACS
November 1, 2008

The PACS market has changed. It is no longer just about the images.

Toshiba sets 'dynamic volume' as new CT frontier
November 1, 2008

Early CT systems delivered insights about the body’s anatomy that were previously impossible.

CR prepares to challenge solid-state digital mammo
November 1, 2008

Since full-field mammography started going digital eight years ago, systems based on flat-panel arrays have dominated. But computed radiography has begun seeping into that market and, if the FDA allows CR companies to apply for streamlined 510(k) approval of mammography upgrades, the trickle of CR products could turn into a flood.

Vendors polish advanced apps with 3T platforms
November 1, 2008

MR vendors have been chipping away at new clinical applications for years. They have pointed to 3T as the means to expand routine practice in ways that are not routine, adding computing engines to handle the massive volumes of data that would gush forth, expanding data pipelines, building out coils with extended channels—in short, creating the infrastructure to support a new diagnostic order. This year, they mean business.

Digital mammography: CR and tomo could change game
November 1, 2008

Full-field digital mammography was built on solid-state technology. The first such machines, introduced eight years ago, were based on flat-panel detectors, a tradition that continued until the commercial introduction of computed radiography a few years ago.

Innovation spurs novel nontraditional applications
November 1, 2008

The inherent strengths of ultrasound—low cost, wide availability, nonionizing radiation—make this modality a favorite to get the diagnostic ball rolling.

Breast imaging shines among ultrasound advances
November 1, 2008

Ultrasound will step into the politically charged environs of women's health and address the vagaries of today's financial challenges at this year's RSNA meeting.





CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy