DiagnosticImaging Members: Login | Register
Diagnostic Imaging Recommended Medical Sites Medline Drugs

Powered by SearchMedica

 
  • Home
  • Blog
  • Conference Reports
  • Case Studies
  • Jobs
  • Product Directory
  • Voice Recognition
  • Low Dose
  • RSNA 2011
  • PET-MR

Home » Conference Reports » Stanford 2006

NewsfromStanford2006

Stanford 2006


View slide show

Stanford2006


 

Overuse of CT challenges pediatric radiologists

Imagers face responsibility for ensuring appropriate use and safety of patients

Deborah R.Dakins
September 1, 2006

One of the biggest mistakes made by specialists is overuse of CT in pediatrics, according to Dr. Donald Frush, chief of pediatric radiology at Duke University. As critical as multislice CT can be in evaluating pediatric patients, it's not the right tool all the time.

In a review of the top mistakes imagers make in pediatric CT imaging, Frush cited overuse as number one during a presentation at the Stanford Multidetector-Row CT symposium in San Francisco.

"Implicit in every CT procedure is an agreement that it is indicated," Frush said. "But 30% to 40% of CT exams have questions about indications. Ultimately, we are responsible for the use of CT, for obtaining diagnostic examinations, and for the safety of our patients."

The problem is not easily addressed, he said, acknowledging the lure of new devices combined with radiology business pressures. But ensuring that scans are designed to answer specific clinical questions is one way to reduce overuse.

Changes in technique and protocol can help counter other common mistakes in pediatric practice. Frush sees poor contrast enhancement as one of these.

Frush also sees overuse of multiphase exams in pediatric practice. At Duke, only about 5% of all body MSCT exams in children are multiphase. But the average he sees in outside practices is 31%.

Pediatric exams typically use kVp values that are too high, Frush said. He recommended considering 80 to 120 kVp in chest, musculoskeletal, and CTA studies.

Another common mistake is failure to anticipate the need to perform reformations. To ensure best image quality when scanning for causes of abdominal pain, obstructions, and airways and in CT angiography, imagers should use the thinnest detector configuration possible, Frush said. Thin slices with a 30% to 50% overlap abet optimal reconstructions.

Pediatric patients should be prepared properly by sedating when necessary and then scanned quickly, Frush said. He recommended using intravenous contrast, which carries a low risk in pediatric populations, when indicated but particularly for abdominal pain. Adjusting dose protocols depending on organ systems is also helpful.

"Chest, MSK, and CTA are all amenable to lower dose scanning because they are intrinsically high contrast," Frush said. "Think about dose thresholds. How much do you really need?"

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Webcasts

Cardiac anatomy for the imager
The rapid evolution of cardiac CT has created a compelling need for imagers to fully understand cardiac anatomy as well as the best methods for imaging it.


A multimedia presentation by Dr. Julie Miller, director of the cardiology vascular program at Johns Hopkins University, addresses these developments.
 

What'sNewonDiagnosticImaging.com


So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012


CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy