NewsFromStanford2008

Stanford 2008


View slide show

StanfordInternationalSymposium2008


 

Ground-glass nodules merit scrutiny for differential diagnosis

By Shalmali Pal | May 16, 2008

Persistent ground-glass nodules in the lungs are worth a closer look, as they are highly associated with malignancy. Dr. Anne Leung offered an overview of how these lesions present on CT imaging at the 2008 Stanford International Symposium on Multidetector-Row CT in Las Vegas. "Ground glass is defined as hazy or decreased attenuation on CT that does not obscure underlying bronchovascular bundles," said Leung, chief of thoracic imaging at Stanford University School of Medicine. "The pathologic correlates that have been described with ground-glass nodules are partial airspace filling, interstitial filling, edema, fibrosis, and neoplastic infiltration." Leung pointed out that ground-glass nodules have two subtypes: pure ground glass and ground glass with solid components. Ground-glass nodules with solid elements are more likely to be malignant, particularly if they persist over three months, she said.

Leung highlighted some of the differential diagnoses that can be made on CT when ground-glass nodules are present:

  • lymphoma
  • focal interstitial fibrosis
  • primary neoplastic diseases and their precursors

Among the primary neoplastic diseases, she described atypical edematous hyperplasia. The CT features of these peripheral lesions are a size of less than 5 mm, round or oval shape, smooth margins, and pure ground-glass appearance.

Focal ground-glass nodules with solid components are also found with bronchoalveolar cell carcinoma. Other CT features to look for are air lucencies, smooth or irregular contours, and slow growth, Leung said. Finally, there is adenocarcinoma, the most common lung cancer in the U.S. CT features of this disease state are focal ground-glass nodules with solid elements, air lucencies, and smooth or irregular contours. Leung concluded that persistent ground-glass nodules are best seen with thin-section imaging. Readers should keep an eye out for solid components and interval growth. Finally, she recommended against evaluating ground-glass nodules with PET studies, as negative results are generally not a reliable indicator of benign disease.
 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.

  • Oldest First
  • Newest First

by alice tollestrup | November 09, 2011 3:26 PM EST

I have had a number of CTs over the past several years showing multiple nodules measuring less then 3mm throughout both lungs too numerous to count resembling ground glass. I have had no doctor in New Mexico who has been helpful in resolving if they can be causing many health problems many I am having since 2002 when I was diagnosed with Chlamydia pneumoniae. Where can I receive help.

alicehtollestrup@g-mail.com





Videos

GE unveils ultra-premium CT

GE unveils ultra-premium CT

The new LightSpeed CT750 HD from GE Healthcare promises a 33% contrast improvement in the body and 47% in the heart, while cutting dose in the body by as much as half. The most significant change, however, may come from the product's ability to acquire data at more than 101 different energy levels, using an approach GE calls spectral imaging. Dominic Smith, GE's general manager of molecular imaging and CT marketing and advanced applications, describes this new capability. Greg Freiherr has the story.
View video

 


Stanford MCDT workstation faceoff

Stanford MCDT workstation faceoff

Seven companies went toe-to-toe in the Stanford MCDT workstation faceoff, their systems driven by 14 radiologists navigating four cases. It was three hours of intense interpretations, packaged into five-minute blocks stacked end to end. Greg Freiherr winds it up in the fastest 90 seconds in radiology.
View video

 


AquilionOne Vegas protocol focuses on patient handling

AquilionOne Vegas protocol focuses on patient handling

Patient throughput makes or breaks an imaging center. At the Spring Valley Imaging Center, one of several in the Nevada Imaging Centers group in Las Vegas, the third U.S. installation of the AquilionOne is being groomed for volume, in terms of not only data acquisition but patients as well. The center is doing advanced studies in the brain and heart but also every routine CT scan possible. Greg Freiherr has the story.
View video

What'sNewonDiagnosticImaging.com


MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012
PET Technique Useful in Challenging Breast Cancer Cases
February 7, 2012


CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy