Study recommends standardized image reject methodology

Douglas Page
May 27, 2008

Digital radiography systems are in common use for medical imaging, yet few studies have examined computed radiography quality performance in terms of reject rates. This lack is due primarily to difficulty in obtaining the data required to calculate reject statistics.

"This problem has been further compounded by the lack of software infrastructure necessary to centrally compile data for radiology departments that have multiple digital capture devices," said David H. Foos of the Clinical Applications Research Laboratory at Carestream Health.

Foos recently described a methodology used to compile a comprehensive database consisting of more than 288,000 CR images from two all-digital radiology departments in a university hospital and a large community hospital in order to perform reject analysis (J Digit Imaging 2008;Apr 30 [Epub ahead of print]). Each database record contains image information such as body part and view position, exposure level, technologist identifier, and reason for rejection.

"Our results suggest that complete and accurate reject analysis in digital radiography is possible, but it requires that quality assurance software tools and associated network infrastructure be combined with rigorous data entry protocols to ensure the integrity of the analysis," Foos said.

Accurate reject analysis provides a platform from which to develop targeted training programs designed to mitigate the largest sources of patient repeat exposures, he said.

The Foos study found the reject rate for CR across both hospital departments and all exam types was 4.4% at the university and 4.9% at the community hospital.

"Positioning errors and anatomy cutoff were the most frequently occurring reasons for rejection, accounting for 45% of rejects at the community hospital and 56% at the university," Foos said.

The next most frequently cited reasons for reject were improper exposure (14% at the community hospital and 13% at the university), followed by patient motion (11% community and 7% university).

"Comprehensive digital radiography QA requires that a mechanism be put into place to force technologists to enter reject data information into a database, preferably before another image can be scanned," Foos said.

He also suggested that a standardized lexicon for reject reasons be organized to eliminate inconsistencies in reject data entry.

"Standardized terminology and definitions for QA deficiencies must be established, along with the associated training, to eliminate inconsistent and inappropriate labeling of rejected images," he said.

Tools such as digital dashboards and device clustering software platforms are now available to assist with QA efforts, Foos said.

"These tools facilitate access to the objective data necessary to analyze and report on reject statistics and digital radiography equipment utilization across an entire institution," he said.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.






TopicIndex

 

ACOs
Cardiac
Case Studies
Colonography
CT
Digital X-ray
Direct Radiography
Elastography
Low-Dose Modalities
Meaningful Use
Molecular Imaging
MRI
 

 

Nuclear
PACS
PET/CT
PET/MR
Practice Management
RIS
Teleradiology
Ultrasound Imaging
Vendors
Voice Recognition
Women's Imaging
All Topics
 


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 


FromPhysiciansPractice

'What They Should Really Teach in Medical School'
Julie Schopps, MD , February 6, 2012
The North Carolina-based pediatrician weighs in on why she thinks the real learning doesn't take place until students are out of the classroom.
Improve EHR Systems by Rethinking Medical Billing
Daniel Essin, MA, MD, February 6, 2012
Separating billing-related data from other clinical documentation and transmitting it to a billing system is not difficult …no matter how the charting is done.
Keeping Your Medical Practice’s Accounts Receivable on Track
P.J. Cloud-Moulds, February 4, 2012
Here are the minimum reports you should be running to keep an eye on your practices A/R.
Healthcare Providers Play Crucial Role in Helping Victims of Abuse
Stephen Hanson, PA-C , February 3, 2012
I would urge each and every one of you to be familiar with the warning signs of abuse, and the resources available to you all as healthcare providers.
Protecting Your Medical Practice's Data
Marisa Torrieri, February 3, 2012
Here's the scoop on how to implement a good data-backup plan at your office.
  • On This Site
  • Most Emailed
  • On This Topic

MostPopular

  • Whole-breast ultrasound brings significant screening benefits

    JAN 15 2010 DIAGNOSTIC IMAGING ASIA PACIFIC READ >>

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • As teleradiology evolves, it changes dramatically, plays growing role in practice

    DEC 15 2010 DIAGNOSTIC IMAGING READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009 DIAGNOSTIC IMAGING EUROPE READ >>

  • Mucinous Adenocarcinoma of Stomach

    JAN 9 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Telemammography Taking Hold

    JAN 24 2012 READ >>

  • Riverain’s Chest X-Ray Comparison Tool Gets FDA Nod

    JAN 11 2012 READ >>

  • Podcast: Implementing a Hybrid PET/MR System

    JAN 30 2012 READ >>

  • Taking Medical Image Sharing to the Cloud

    JAN 19 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Radiology Comic: Doctors Cheating

    JAN 31 2012 READ >>

  • CNN Look at Radiology Exam "Cheating" Misses the Mark

    JAN 24 2012 READ >>

  • Columbus Radiology Launches Imaging Ordering App

    JAN 19 2012 READ >>

  • Radiology Comic: MRI de Cabeza

    JAN 4 2012 READ >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy