Fibroid embolization agent influences treatment result

Contrast-enhanced MR sets higher standard for measuring success of nonsurgical procedure

Emily Hayes
February 11, 2006

A controversy simmering since last year's meeting of the Society of Interventional Radiology resurfaced during the RSNA meeting when Yale researchers presented evidence that a particular type of polyvinyl alcohol(Drug information on polyvinyl alcohol) particles, used to embolize bleeding uterine fibroids, is less effective than other products. They concluded that the use of Contour SE could lead to greater fibroid recurrence and repeat embolization procedures.

Using contrast-enhanced MR scans, the Yale researchers compared long-term results, including recurrence of fibroids and fibroid-related symptoms, for uterine arterial embolization (UAE) using three different agents:

- Contour PVA (classic polyvinyl alcohol(Drug information on alcohol) particles), Boston Scientific;

- Contour SE (spherical PVA or sPVA), Boston Scientific; and

- Embosphere (gelatin microspheres), Biosphere Medical.

Contour SE proved significantly less effective than either gelatin microspheres (GM) or classic polyvinyl alcohol particles, according to the study findings.

"All embolic agents are not created equal, even though they are all FDA-approved. Practitioners performing UAE should avoid using spherical PVA and instead use gelatin microspheres or traditional PVA," said Dr. Michael Tal, director of interventional radiology research at Yale.

Traditionally, the test of an embolic agent's effectiveness has been improvement in fibroid-related symptoms and quality of life following UAE, as well as reduction in fibroid volume on standard MRI. But researchers are beginning to use the more demanding yardstick of contrast-enhanced MRI, which reveals residual perfusion in fibroids post-UAE. The goal of UAE is to infarct fibroids. If MRI shows they are only partially infarcted, and portions still have a blood supply, it is likely that they will recur.

In studies reported at the 2005 SIR meeting, Contour SE demonstrated good initial results but ultimately yielded a higher incidence of fibroid recurrence on contrast-enhanced MRI. The studies suggested that particle size was the difference.

A 2004 protocol devised by Boston Scientific called for an sPVA particle size of 500 to 700 microg, 700 to 900 microg, or 900 to 1200 microg. The physician should embolize both uterine arteries to complete stasis, defined as stoppage of the blood flow in the main uterine artery for 10 cardiac beats. The 2004 protocol recommends that users wait for five minutes after stasis to look for evidence of particle redistribution, according to the company.

But in 2005, following the release of new research with contrast-enhanced MRI, Boston Scientific suggested a revised UAE protocol, calling for sPVA with larger microspheres (700 to 900 microg or 900 to 1200 microg). Instructions about embolization to stasis remain unchanged.

It's questionable whether traditional UAE success measures of symptom relief and improvement of quality of life should now be replaced, said Scott Pisarczyk, vice president of marketing for oncology at Boston Scientific.

"There is debate about what is the true measure of success-if the patient feels better and the size of her fibroids has decreased, or the results of contrast-enhanced MR," he said.

If practitioners want to use contrast-enhanced MRI as a determinant of success, they should follow the revised protocol, he said. A study presented at the 2005 SIR meeting by French authors and sponsored by Boston Scientific showed that use of the larger particles and embolization to stasis resulted in an 83% rate of complete fibroid infarction.

Some experts say the new protocol is not practical. To be successful, a practitioner must force the larger Contour SE particles through a microcatheter with a luminal diameter smaller than the nominal size of the particles, said Dr. Robert Worthington-Kirsch, founder of Image Guided Surgery Associates in Philadelphia.

"I believe that Contour SE should not be used for UAE. Although there is some (not conclusive) evidence that UAE can be effective if performed using the revised protocol, that protocol is technically difficult to achieve. UAE is far easier to accomplish and has better documented results with hydrogel microspheres, so why should anyone bother with Contour SE?" Worthington-Kirsch said.

The Yale study involved 101 patients embolized with either PVA (300 to 500 microg), GM (500 to 700 microg), or sPVA (500 to 700 microg). Contrast-enhanced MR findings were correlated with quality of life survey results.

Incomplete infarction, as gauged by residual enhancement on MR, occurred in 75% of sPVA cases, 41% of PVA cases, and only 22% of GM cases. The differences between sPVA and the other two agents were statistically significant, while the difference between GM and PVA was not.

Patients treated using Contour SE were at higher risk of residual enhancement than those who received Contour PVA or Embosphere, according to medical student Jorge Galvez, who presented the results at the RSNA and won a trainee research prize for the work. However, differences in symptom recurrence, as reported on the patient survey, were not statistically significant for the three agents.

Tal, who supervised the study, said that while Contour SE proved less effective based on contrast-enhanced MR, the team is now evaluating another sPVA compound. That agent, distributed by Terumo Medical, may yield results comparable to GM, he said.

Classic PVA particles, which have been used effectively for decades, are now obsolete according to Worthington-Kirsch. They may not reliably provide complete vessel occlusion and should not be used for UAE.

"It (GM) works well and is easy to use. In my opinion, this is the current standard by which other materials must be measured," he said.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.






TopicIndex

 

ACOs
Cardiac
Case Studies
Colonography
CT
Digital X-ray
Direct Radiography
Elastography
Low-Dose Modalities
Meaningful Use
Molecular Imaging
MRI
 

 

Nuclear
PACS
PET/CT
PET/MR
Practice Management
RIS
Teleradiology
Ultrasound Imaging
Vendors
Voice Recognition
Women's Imaging
All Topics
 


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 


FromPhysiciansPractice

'What They Should Really Teach in Medical School'
Julie Schopps, MD , February 6, 2012
The North Carolina-based pediatrician weighs in on why she thinks the real learning doesn't take place until students are out of the classroom.
Improve EHR Systems by Rethinking Medical Billing
Daniel Essin, MA, MD, February 6, 2012
Separating billing-related data from other clinical documentation and transmitting it to a billing system is not difficult …no matter how the charting is done.
Keeping Your Medical Practice’s Accounts Receivable on Track
P.J. Cloud-Moulds, February 4, 2012
Here are the minimum reports you should be running to keep an eye on your practices A/R.
Healthcare Providers Play Crucial Role in Helping Victims of Abuse
Stephen Hanson, PA-C , February 3, 2012
I would urge each and every one of you to be familiar with the warning signs of abuse, and the resources available to you all as healthcare providers.
Protecting Your Medical Practice's Data
Marisa Torrieri, February 3, 2012
Here's the scoop on how to implement a good data-backup plan at your office.
  • On This Site
  • Most Emailed
  • On This Topic

MostPopular

  • Whole-breast ultrasound brings significant screening benefits

    JAN 15 2010 DIAGNOSTIC IMAGING ASIA PACIFIC READ >>

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • As teleradiology evolves, it changes dramatically, plays growing role in practice

    DEC 15 2010 DIAGNOSTIC IMAGING READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009 DIAGNOSTIC IMAGING EUROPE READ >>

  • Mucinous Adenocarcinoma of Stomach

    JAN 9 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Telemammography Taking Hold

    JAN 24 2012 READ >>

  • Riverain’s Chest X-Ray Comparison Tool Gets FDA Nod

    JAN 11 2012 READ >>

  • Podcast: Implementing a Hybrid PET/MR System

    JAN 30 2012 READ >>

  • Taking Medical Image Sharing to the Cloud

    JAN 19 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Radiology Comic: Doctors Cheating

    JAN 31 2012 READ >>

  • CNN Look at Radiology Exam "Cheating" Misses the Mark

    JAN 24 2012 READ >>

  • Columbus Radiology Launches Imaging Ordering App

    JAN 19 2012 READ >>

  • Radiology Comic: MRI de Cabeza

    JAN 4 2012 READ >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy