Program reduces medication errors during MR and CT procedures

By James Brice | May 27, 2009

Medication errors may arise less often in a busy hospital radiology department than in other inpatient services, but they can cause more serious damage when they do happen. Radiologists at Boston-based Beth Israel Deaconess Medical Center came to these conclusions after evaluating 27 months of high-tech medical imaging experience. They used their data to identify the causes of errors and devise strategies to address them.

The effort is part of a hospital-wide effort to eliminate medication-related mistakes by 2012 and to comply with a Joint Commission on Accreditation of Healthcare Organizations program aimed at medical error reduction.

Chief investigator Dr. Gerwin Williams discovered from his computer-assisted evaluation of 38,268 contrast-enhanced CT and 26,888 enhanced MRI procedures that from one perspective, the radiology department had performed well. He uncovered 286 medication-related errors that arose during 0.4% of the studies. By comparison, the 2006 edition of the United States Pharmacopeia reported results from a five-year study showing a 5% medication error rate in radiology departments.

But from another angle, the Beth Israel Deaconess experience raised concerns. The harm rate of CT- and MR-related medication errors was about 6%. Fifteen (5%) of the medication-related errors involved temporary harm requiring hospitalization, and four (1%) cases may have caused permanent harm, Williams said in a presentation at the 2008 RSNA meeting.

The rate was highest among incidents that did not involve a contrast agent. Only two cases in this category were identified, but both involved possible permanent damage.

Williams noted that radiology's 6% overall harm rate was half the 12% rate predicted by the Pharmacopeia, and was generally in the range of harm rated for other types of medical departments reported in the medical literature. A Canadian study involving all departments at four hospitals, for example, came up with 7.5% medication-adverse event rate (CMAJ 2004;170[11]:1678), though Williams warned that department-to-department comparisons are problematic because of differing levels of care.

Four types of problems were classified for the 258 intravenous contrast-related medication errors at Beth Israel Deaconess:
• 119 CT contrast extravasations, with 46 requiring plastic surgery consults
• 95 CT contrast reactions, with 10 leading to possible temporary harm and two to permanent injury
• eight MR extravasations, with one needing a plastic surgery consult
• 36 MR contrast reactions, with nine associated with possible temporary harm

The automated database search uncovered 28 medication errors that did not involve intravenous contrast administration. Eleven involved administration of the wrong drug without causing harm. Seven were medication reactions, with one possibly involving permanent harm.

One of six cases involving wrong dosages led to possibly permanent harm. For three patients, administration was halted when symptoms of a known allergy were observed, and in one case, gadolinium contrast was erroneously administered to a patient with a low estimated glomerular filtration rate, but it caused only temporary harm.

These findings served as the basis for a root cause analysis that helped radiology staff identify preventive measures. It recommended eliminating all but one vial option for epinephrine(Drug information on epinephrine) administration to address dosing problems. Electronic flagging techniques were implemented to help identify patients with a history of contrast reactions and to identify discrepant protocol-study requests.

Additional protection was secured by labeling all medications on procedural trays, with a designated timeout period during each case to verify that the correct drug was selected. Point-of-service creatinine testing in the MRI and CT suites was established to avoid nephrotoxic reactions.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.






TopicIndex

 

ACOs
Cardiac
Case Studies
Colonography
CT
Digital X-ray
Direct Radiography
Elastography
Low-Dose Modalities
Meaningful Use
Molecular Imaging
MRI
 

 

Nuclear
PACS
PET/CT
PET/MR
Practice Management
RIS
Teleradiology
Ultrasound Imaging
Vendors
Voice Recognition
Women's Imaging
All Topics
 


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 


FromPhysiciansPractice

Tax Schemes Every Physician Should Avoid
Ike Devji, JD, January 31, 2012
The next 60 days marks the final push to sell physicians across the United States tax plans of both good and questionable value.
Boosting Collections at Your Medical Practice: Whose Job Is It?
P.J. Cloud-Moulds, January 28, 2012
Embrace the relationship between your billing company and your medical practice staff.
Managing Difficult Medical Practice Employees
Shelly K. Schwartz, January 27, 2012
Tips for transforming immature staff members into great employees.
Prevent Physician Distraction When Using mHealth Technology
Aubrey Westgate, January 25, 2012
As more and more physicians use handheld mobile technology in their day-to-day work, some critics are raising concerns about “distracted doctoring.”
Can That Applicant Do the Job at Your Medical Practice?
Karen Zupko, January 25, 2012
If like many communities, yours has significant numbers of non-English speaking people with whom neither you nor your staff are able to converse, your practice is at a serious disadvantage.
  • On This Site
  • Most Emailed
  • On This Topic

MostPopular

  • Whole-breast ultrasound brings significant screening benefits

    JAN 15 2010 DIAGNOSTIC IMAGING ASIA PACIFIC READ >>

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • As teleradiology evolves, it changes dramatically, plays growing role in practice

    DEC 15 2010 DIAGNOSTIC IMAGING READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009 DIAGNOSTIC IMAGING EUROPE READ >>

  • Bilateral Pulmonary Embolism

    DEC 13 2011 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Telemammography Taking Hold

    JAN 24 2012 READ >>

  • Riverain’s Chest X-Ray Comparison Tool Gets FDA Nod

    JAN 11 2012 READ >>

  • Taking Medical Image Sharing to the Cloud

    JAN 19 2012 READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009DIAGNOSTIC IMAGING EUROPE READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Columbus Radiology Launches Imaging Ordering App

    JAN 19 2012 READ >>

  • CNN Look at Radiology Exam "Cheating" Misses the Mark

    JAN 24 2012 READ >>

  • Radiology Comic: MRI de Cabeza

    JAN 4 2012 READ >>

  • Radiology Comic: Doctors Cheating

    JAN 31 2012 READ >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy