DiagnosticImaging Members: Login | Register
Diagnostic Imaging Recommended Medical Sites Medline Drugs

Powered by SearchMedica

 
  • Home
  • Blog
  • Conference Reports
  • Case Studies
  • Jobs
  • Product Directory
  • Voice Recognition
  • Low Dose
  • RSNA 2011
  • PET-MR

Home »

Diagnostic Imaging. Vol. 31 No. 10
 

3D breast MR technique offers exceptional detail

Isotropic acquisition speeds scan, produces better visualization of lesions, and may obviate biopsies

By Greg Freiherr | October 6, 2009

An MR technique that acquires data radially produces images of the breast with such detail that its developers at the University of Wisconsin believe it may eliminate the need for some biopsies. The breast MR technique, which characterizes lesions depending on the in- and outflow of contrast media, may prove especially helpful in characterizing benign lesions that share some MR characteristics with cancerous ones.

As with conventional breast MR exams, the UW technique requires a contrast agent to be injected intravenously. The contrast flows into the vasculature of the breasts, illuminating all blood vessels. But it tends to remain longest in those feeding healthy tissue and benign lesions. This is because cancerous lesions grow too fast for the blood vessels that feed them to develop correctly.

The defective vessels leak the gadolinium-based contrast faster than healthy ones. Consequently, healthy tissues and benign lesions tend to demonstrate a clearly different wash-in and wash-out pattern of contrast than cancerous lesions. This is not always the case, however.

Some lesions accumulate contrast quickly, a wash-in hallmark of cancer, but then wash out at a slower pace, a characteristic typical of benign lesions. This is where conventional breast MR sequences fall flat.

“When you get those kinds of lesions, you go back to your T2-weighted images and see if there are certain morphological characteristics that would indicate that the lesion is likely to be benign,” said Walter Block, a UW-Madison associate professor of biomedical engineering and medical physics.

“Unfortunately, T2 imaging today is typically done in the sagittal plane with a sequence like fast spin-echo or turbo spin-echo. So the resolution in this slice direction is rather poor and you have gaps in between the slices.”

The UW technique, called 3DPR-SSFP (3D projection steady-state free precession), is geared specifically to overcoming this problem. When using the technique, data are acquired as an isotropic volume that can be sliced and viewed from any perspective. This allows lesions to be examined in detail, according to Block.

The physical characteristics of these lesions can be telltale indicators of whether they are malignant. Those with smooth edges often are benign; ones with jagged edges typically are cancerous.

Because volumetric acquisitions can be sliced at any angle and across any point, the shape of lesions also can be assessed completely. Single-plane acquisitions are not so helpful.

“If the morphology that would tip you off that something is benign is in a plane other than the one you’ve acquired, you’re out of luck,” Block said.

By capturing a volume of data that can be sliced in any direction, only one 3D sequence is needed to capture a complete set of data for 2D reconstructions. The method also allows the separate examination of data from fat and data from water. Differentiating fat is useful because it makes up a large portion of the breast.

“Most of the time radiologists concentrate on water images, because disease is rarely associated with fat,” Block said. “But sometimes fat images of the breast are useful. The boundaries of a lesion often stand out very clearly when [it is] embedded in fat.”

The potential of the UW technique has been shown in studies of about 20 patients at the University of Wisconsin Hospital. Block and colleagues are expanding their clinical evaluation with more patients. Additional feedback may soon come from the University of Toronto and Michigan State University, where researchers are preparing to conduct their own assessments of the technique.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.






TopicIndex

 

ACOs
Cardiac
Case Studies
Colonography
CT
Digital X-ray
Direct Radiography
Elastography
Low-Dose Modalities
Meaningful Use
Molecular Imaging
MRI
 

 

Nuclear
PACS
PET/CT
PET/MR
Practice Management
RIS
Teleradiology
Ultrasound Imaging
Vendors
Voice Recognition
Women's Imaging
All Topics
 


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 


FromPhysiciansPractice

'What They Should Really Teach in Medical School'
Julie Schopps, MD , February 6, 2012
The North Carolina-based pediatrician weighs in on why she thinks the real learning doesn't take place until students are out of the classroom.
Improve EHR Systems by Rethinking Medical Billing
Daniel Essin, MA, MD, February 6, 2012
Separating billing-related data from other clinical documentation and transmitting it to a billing system is not difficult …no matter how the charting is done.
Keeping Your Medical Practice’s Accounts Receivable on Track
P.J. Cloud-Moulds, February 4, 2012
Here are the minimum reports you should be running to keep an eye on your practices A/R.
Healthcare Providers Play Crucial Role in Helping Victims of Abuse
Stephen Hanson, PA-C , February 3, 2012
I would urge each and every one of you to be familiar with the warning signs of abuse, and the resources available to you all as healthcare providers.
Protecting Your Medical Practice's Data
Marisa Torrieri, February 3, 2012
Here's the scoop on how to implement a good data-backup plan at your office.
  • On This Site
  • Most Emailed
  • On This Topic

MostPopular

  • Whole-breast ultrasound brings significant screening benefits

    JAN 15 2010 DIAGNOSTIC IMAGING ASIA PACIFIC READ >>

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • As teleradiology evolves, it changes dramatically, plays growing role in practice

    DEC 15 2010 DIAGNOSTIC IMAGING READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009 DIAGNOSTIC IMAGING EUROPE READ >>

  • Mucinous Adenocarcinoma of Stomach

    JAN 9 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Telemammography Taking Hold

    JAN 24 2012 READ >>

  • Riverain’s Chest X-Ray Comparison Tool Gets FDA Nod

    JAN 11 2012 READ >>

  • Podcast: Implementing a Hybrid PET/MR System

    JAN 30 2012 READ >>

  • Taking Medical Image Sharing to the Cloud

    JAN 19 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Radiology Comic: Doctors Cheating

    JAN 31 2012 READ >>

  • CNN Look at Radiology Exam "Cheating" Misses the Mark

    JAN 24 2012 READ >>

  • Columbus Radiology Launches Imaging Ordering App

    JAN 19 2012 READ >>

  • Radiology Comic: MRI de Cabeza

    JAN 4 2012 READ >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy