January 25, 2005

The prognostic value of cardiac MR was a prominent theme last week at the Society for Cardiovascular Magnetic Resonance meeting in San Francisco. Dr. Rishi Kaushal, a CMR researcher at the University of California, Los Angeles, presented results demonstrating that myocardial infarction size measured with cine and delayed-enhancement MR can predict the risk of mortality posed by the injury.

The rationale for Kaushal's study was a paradox in criteria for selecting candidates for an implantable cardioverter defibrillator (ICD). Several studies indicate that patients thought to be at high risk of sudden cardiac death have a higher mortality rate than patients in lower risk groups.

Patients with an ejection fraction between 31% and 40% and unsustained ventricular or inducible tachycardia qualify for an ICD. No clear guidelines for implantation exist for patients with ejection fractions greater than 40%, however, and they account for most of the patients who die suddenly because of their condition, Kaushal said.

Kaushal and colleagues at UCLA and Cedars-Sinai Medical Center in Los Angeles expected that additional clinical criteria would clarify the situation. His study examined whether MI size measured with cine and delayed-enhancement MR gives clinicians an additional indicator regarding who should obtain an ICD.

Kaushal's investigation was based on a study of 100 patients with coronary artery disease. Their mean age was 66 years, and 87% of the group was male. About six of 10 subjects had a previous MI, 23% had diabetes, and 49% were hypertensive. For the study, they were initially imaged with cine and delayed-enhancement MR as part of a routine cardiac examination. The mean left ventricular ejection fraction among the group was 34%.

Kaushal also measured the location and size of the previous MI. Regional wall thickening and contrast enhancement were measured using a 17-segment anatomic model. Viable segments exhibited less than 25% delayed enhancement.

Outcome data collected an average of 25 months later found that 15 subjects had died from cardiac events and another 26 had undergone myocardial revascularization or hospitalization to treat unstable angina or congestive heart failure. DE-MRI found myocardial damage suggesting a previous MI in nine of 10 patients.

Using Cox multivariant analysis, Kaushal determined that an infarction of greater than 15% of left ventricular mass and diminished ejection fraction were the only statistically significant predictors of death. The results led him to conclude that the extent of MI can predict if a patient is susceptible to a death that could be avoided with ICD implantation.

For more information from the Diagnostic Imaging archives:

Multisequence stress CMR shows promise

Late-enhancement MRI finds diagnostic roles

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.

Expanded MR protocol improves assessment of myocardial infarction

Expanded MR protocol improves assessment of myocardial infarction

High-field cardiac MR imaging enjoys continued strong progress

MSCT matches cardiac MRI for emergency myocardial infarction assessment

Report from SCMR: Cardiac MRI spots stealthy heart attacks in diabetic patients

Report from SCMR: Late-enhancement MR predicts susceptibility to future cardiac death





View magazine archives »

Sponsored White Papers


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 
What's New on DiagnosticImaging.com

So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy