DiagnosticImaging Members: Login | Register
Diagnostic Imaging Recommended Medical Sites Medline Drugs

Powered by SearchMedica

 
  • Home
  • Blog
  • Conference Reports
  • Case Studies
  • Jobs
  • Product Directory
  • Voice Recognition
  • Low Dose
  • RSNA 2011
  • PET-MR

Home » Daily News

Diagnostic Imaging.
 

Elastography advances feature prominently among ultrasound exhibits

By John Bonner | March 10, 2010

The exhibition booths occupied by vendors of ultrasound systems at ECR 2010 are likely to be very busy places throughout the congress. Difficult economic conditions are causing a dip in global demand for the more capital-intensive modalities like CT and MRI, and hospital managers are keen for their staff to explore the clinical potential of this versatile and cost-effective technology.

Delegates are eager to hear more about the latest hardware and software applications being unveiled by this sector’s major names, and the biggest buzz emanating from ultrasound exhibits is around elastography. The technique uses mechanical compression to analyze the stiffness of different tissues; fibrotic or cancerous lesions are usually considerably more resistant to compression than healthy tissue. The technique has developed alongside conventional B-mode ultrasonography and is also attracting interest from companies seeking to apply it in combination with other imaging modalities, like MRI.

Hitachi Medical Systems has been a pioneer in the clinical development of elastography and is offering its own version of this technology, Hitachi Real-Time Tissue Elastography (HiRTE), as a key application on its new compact ultrasound platform, Hi Vision Avius, which follows last year’s launch of the Hi Vision Preirus.

Real-time sonoelastography has been shown to be useful in differential diagnosis of breast cancer. (Provided by Hitachi)
Elastography may also have applications in cases of rectal cancer (Provided by Hitachi)

The application is part of a package of advanced product features on the new machine, including established technologies such as Hi Rez+ (tissue adaptive filtering), HdTHI (high-definition dynamic tissue harmonic imaging) and Hi Com (frequency and spatial compounding), as well as new features such as RVS (real-time virtual sonography). The latter is a software application that uses magnetic tracking sensors on the ultrasound transducer to display real-time freehand ultrasound images alongside synchronous other images.

“Elastography-based palpation using the ultrasound transducer is a simple, noninvasive, real-time technique that improves the differentiation of benign and malignant disease in a range of clinical applications, including the breast, thyroid, prostate, pancreas, liver, and many more,” said Ellison Bibby, Hitachi’s European product manager for ultrasound. “Ease of use, freehand manipulation, and real-time feedback are fundamental attributes that have allowed elastography to become an efficient and easy-to-perform component of the ultrasound examination. Recognising that this modality has been clinically validated as an accurate and reproducible technique that can provide significant diagnostic benefit in routine clinical applications, Hitachi has added this option to its full platform range.”

Another company that has been at the forefront of developments in elastography is SuperSonic Imagine, based in Aix-en-Provence, France. The company made its ECR debut last year, demonstrating a breast examination package on its Aixplorer ultrasound system. This year it is introducing two new applications for abdominal and thyroid examinations.

SuperSonic Imagine describes itself as a “theragnostic” company, believing that its software for the high-speed analysis of shear waves will have applications at all stages of the treatment process. Its products are reportedly equally useful in the diagnosis and characterization of lesions, in planning and in guiding interventions such as biopsies and tissue ablation, and in monitoring response to treatment.

Other, more established, players in the radiology field are equally convinced of the potential of this new technology. Toshiba Medical Systems is offering a quantitative elastography application in its new Aplio MX platform, which is being shown for the first time at ECR 2010 and is designed to provide a cheaper alternative to its top-of-the-range Aplio XG model. In due course, the product will be available with another development called ASQ, or acoustic structure quantification. The software package can analyze echo signal data at a resolution more than 100 times higher than normal gray-scale or color flow images by using a special hardware extension, the Toshiba ultrasound raw data interface.

ASQ (acoustic structure quantification) of the liver in a patient with severe fibrosis (grade 3). In region of interest, elevated average value of Cm2 with frequency distribution shifted to the right. (Provided by Toshiba)

“We believe that ASQ, together with other advanced applications such as precision imaging and quantitative elastography, enables us to provide valuable packages of diagnostic tools for the clinician to perform comprehensive ultrasound diagnostics in specific regions of the body such as the abdomen,” said Joop van de Kant, clinical marketing manager for the company’s European ultrasound business.

Philips is another of the big names offering elastography. Its version is part of an advanced breast imaging package available on the latest version of the company’s iU22 ultrasound system. Philips has expanded its range with the Vision 2010 upgrade, the fifth major enhancement of the iU22 device. Elastography is provided by an L12-5 transducer and an advanced breast tissue-specific imaging preset that helps users to differentiate relative stiffness of tissue.

Siemens is presenting its own version of elastography with the latest upgrade to the Acuson S2000 ultrasound platform, which includes enhancements to its acoustic radiation force imaging (ARFI), virtual touch tissue imaging, and virtual touch tissue quantification technologies.

Image of large breast fibroadenoma taken using Siemens’ Acuson 2000 system. (Provided by Siemens)

“These leading-edge technologies redefine the use of ultrasound in the diagnosis, treatment, and therapy of diseases affecting areas of the body that cannot be examined through physical palpation, for example, the liver,” said Norbert Gaus, CEO of Siemens ultrasound business unit.

The product gives a numerical value to tissue stiffness at a precise anatomical location, which helps to identify early-stage liver disease. Using intelligent algorithms that automatically calculate the values, it also addresses challenges related to user-dependence and variability, as well as consistency and reproducibility.

Perhaps because of its role in developing technology to combine elastography with MRI, GE Healthcare appears to be putting less stress on elastography and ultrasound. Its announcement about the latest release of its Logiq E9 platform emphasises the device’s broad-ranging clinical utility for improving image quality and productivity in pediatric, vascular, and cardiac imaging. “The breakthrough 2010 enhancements extend Logiq E9’s extraordinary imaging, expert tools, and easy workflow to more clinical specialties. Innovative agile acoustic architecture, E-Series transducers, expert tools like fusion, and a new cardiac suite of tools combine to create capabilities that are truly expanding the boundaries of ultrasound,” said Brian McEathron, general manager of the general imaging and ultrasound division.

Seven new transducers are being introduced in this release, covering cardiac, vascular, and pediatric applications. Vascular enhancements include auto IMT (intima media thickness) and cardiac tools include Q-analysis, tissue velocity imaging, and color M-mode.

Note: a version of this article appeared in the 2010 ECR Today newspaper.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.

  • Oldest First
  • Newest First

by Marianne Cohn | March 29, 2010 2:23 PM EDT

www.siemens.com/strain






TopicIndex

 

ACOs
Cardiac
Case Studies
Colonography
CT
Digital X-ray
Direct Radiography
Elastography
Low-Dose Modalities
Meaningful Use
Molecular Imaging
MRI
 

 

Nuclear
PACS
PET/CT
PET/MR
Practice Management
RIS
Teleradiology
Ultrasound Imaging
Vendors
Voice Recognition
Women's Imaging
All Topics
 


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 


  • On This Site
  • Most Emailed
  • On This Topic

MostPopular

  • Whole-breast ultrasound brings significant screening benefits

    JAN 15 2010 DIAGNOSTIC IMAGING ASIA PACIFIC READ >>

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • As teleradiology evolves, it changes dramatically, plays growing role in practice

    DEC 15 2010 DIAGNOSTIC IMAGING READ >>

  • Delayed side effects persist in IV iodinated contrast media

    MAY 28 2009 DIAGNOSTIC IMAGING EUROPE READ >>

  • Mucinous Adenocarcinoma of Stomach

    JAN 9 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Telemammography Taking Hold

    JAN 24 2012 READ >>

  • Riverain’s Chest X-Ray Comparison Tool Gets FDA Nod

    JAN 11 2012 READ >>

  • Podcast: Implementing a Hybrid PET/MR System

    JAN 30 2012 READ >>

  • Taking Medical Image Sharing to the Cloud

    JAN 19 2012 READ >>

MostPopular

  • CNN Investigation Targets Radiology Board Exam Cheating

    JAN 13 2012 READ >>

  • Radiology Comic: Doctors Cheating

    JAN 31 2012 READ >>

  • CNN Look at Radiology Exam "Cheating" Misses the Mark

    JAN 24 2012 READ >>

  • Columbus Radiology Launches Imaging Ordering App

    JAN 19 2012 READ >>

  • Radiology Comic: Bad Apple

    JAN 17 2012 READ >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy