Glaucoma drainage implants and MRI safety

Frank Shellock
October 3, 2005

A drainage implant or device, also known as a tube shunt, is implanted in the sclera of patients with glaucoma to maintain an artificial drainage pathway and control intraocular pressure. Intraocular pressure is lowered when aqueous humor flows from inside the eye through the tube into the space between the plate that rests on the scleral surface and surrounding fibrous capsule.(1-3)

The implantation of a drainage device is used to treat glaucoma that is refractory to medical and standard surgical therapy.(1-3) These are usually cases in which standard drainage procedures have failed or patients have a poor prognosis. These cases involve failed trabeculectomy, buphthalmos and juvenile glaucoma, neovascular glaucoma and glaucoma secondary to uveitis, traumatic glaucoma, cataract with glaucoma, and high-risk primary glaucoma.(1-3)

For certain glaucoma drainage implants, radiographic findings may suggest detection of an orbital foreign body if the ophthalmic history is unknown, as reported by Ceballos and Parrish.(3) In this case report, a patient was denied an MRI examination for fear of dislodging an apparent "metallic foreign body." In fact, the patient had a Baerveldt glaucoma drainage implant, which was mistakenly identified as an orbital metallic object based on its radiographic characteristics (i.e., due to the presence of barium-impregnated silicone.(3)

At least one glaucoma drainage implant, the ExPRESS miniature glaucoma shunt (Optonol, Neve Ilan, Israel) is made from 316L stainless steel.(4,5) However, many glaucoma drainage implants are made from nonmetallic materials and are safe for patients undergoing MRI procedures.(3) Commonly used devices that do not contain metal include the following:

  • Baerveldt glaucoma drainage implant (Pharmacia, Kalamazoo, MI)

  • Krupin-Denver eye valve to disc implant (E. Benson Hood Laboratories, Pembroke, MA)

  • Ahmed glaucoma valve (New World Medical, Rancho Cucamonga, CA)

  • Molteno drainage device (Molteno Ophthalmic, Dunedin, New Zealand)

  • Joseph valve (Valve Implants, Hertford, England)

Frank G. Shellock, Ph.D., FACC, FACSM, is an adjunct clinical professor of radiology and medicine at Keck School of Medicine, University of Southern California, and Institute for Magnetic Resonance Safety, Education, and Research.

www.MRIsafety.com

www.IMRSER.org

References

1. Sidoti PA, Baerveldt G. Glaucoma drainage implants. Curr Opin Ophthalmol 1994;5:85-98.

2. Hong CH, Arosemena A, Zurakowski D, Ayyala RS. Glaucoma drainage devices: a systematic literature review and current controversies. Surv Ophthalmol 2005;50:48-60.

3. Ceballos EM, Parrish RK. Plain film imaging of Baerveldt glaucoma drainage implants. AJNR 2002;23;935-937.

4. Traverso CE, De Feo F, Messas-Kaplan A, et al. Long term effect on IOP of a stainless steel glaucoma drainage implant (Ex-PRESS) in combined surgery with phacoemulsification. Br J Ophthalmol 2005;89:425-429.

5. Dahan E, Carmichael TR. Implantation of a miniature glaucoma device under a scleral flap. J Glaucoma 2005;14:98-102.

 

Join the Conversation

Want to join the conversation? Just sign in or register today to become part of our growing, online community.





Article Tools
Sponsored White Papers


SponsoredResources


OptumInsight
Acadiana Computer Systems, Inc. gains a 100% ROI on their radiology billing


Key Equipment Finance
Michiana Hematology Oncology Success Story


Barco
Multi-modality breast imaging using RapidFrame™ technology


Siemens
3D Ultrasound of the Breast


Ziosoft, Inc.
PhyZiodynamic Solutions: Applying Supercomputing to Patient Care


Siemens
Easy Guide to Low Dose


Medrad
Improving Clinical Outcomes and Workflow
Toshiba America Medical Systems
Minimizing dose, sedation in pediatric CT

 

View All

 
What's New on DiagnosticImaging.com

So, Imaging Technologist, You Want to Be Considered a Medical Professional
February 10, 2012
MRI Technique Shows Success of MS Drug Copaxone
February 9, 2012
Early CT Angiography Identifies Recurrent Stroke Risk
February 9, 2012
Podcast: Using MRI in the Operating Room
February 8, 2012
PET with FDG May Predict Outcomes in Triple-Negative Breast Cancer
February 8, 2012
Featured White Paper


More white papers >>



CancerNetwork | CME LLC | ConsultantLive | Diagnostic Imaging | Musculoskeletal Network | OBGYN.net | PediatricsConsultantLive |
Physicians Practice | Psychiatric Times | SearchMedica | Medical Resources

© 1996 - 2012 UBM Medica LLC, a UBM company
Privacy Statement - Terms of Service - Advertising Information - Editorial Policy Statement - UBM Medica Network Privacy Policy