|Articles|October 5, 2011

Lower Contrast Dose Works for MDCT Angiography

Author(s)Todd Neff

Radiologists can boost patient safety without significantly affecting the quality of the images by cutting the dose of contrast media in coronary CT angiography, according to a new study in the American Journal of Roentgenology.

Radiologists can boost patient safety without significantly affecting the quality of the images by cutting the dose of contrast media in coronary CT angiography, according to a new study in the American Journal of Roentgenology.

An analysis of 108 CT angiography studies done using a 320-detector-row CT scanner found that a contrast media protocol based on 60 milliliters of iopamidol “had sufficient enhancement in more than 96 percent of coronary segments,” said Frank Rybicki, MD, of Brigham and Women’s Hospital in Boston, and one of the authors of the study.

Many centers use a higher iodine load, one comparable to 80 milliliters of iopamidol, the study’s authors said. It’s overkill, the study found.

All patients were imaged with a standardized protocol: iopamidol 370 followed by 40 mL of saline, both administered at a rate of 6 mL/s. Two radiologists assessed image quality throughout the coronary arteries. While those receiving the equivalent of 80 milliliters of iopamidol had slightly better image quality, the extra contrast, Rybicki said, “means unnecessary costs and increased risk of contrast-induced nephropathy (CIN) to the patients.” The risk of CIN is of special concern for these patients because they commonly have a renal insufficiency, a major risk factor for CIN, he added.

The analysis of patients with body mass indexes greater than 30 found that 92 percent of coronary segments had sufficient enhancement, which Rybicki said supports the general use of 60 milliliters of iopamidol for CT angiography done on 320 detector row CT scanners.


Related to this article

Does kV Still Matter in Photon-Counting CT?
Emerging research demonstrates the increasing stability of attenuation on clinically relevant VMIs with photon-counting CT and a redefined role of kV that may have implications for longitudinal quantitative CT.
CT Radiation Dosing: Where Things Stand, Part 2
In the second of a two-part interview, Kalpana Kanal, PhD, and Mahadevappa Mahesh, MS, PhD, FAPPM, FACR, discussed future directions for research on CT radiation dosing, including the potential of indication-specific diagnostic reference levels (DRLs).
CT Radiation Dosing: Where Things Stand, Part 1
In the first of a two-part interview, Kalpana Kanal, PhD, and Mahadevappa Mahesh, MS, PhD, FAPPM, FACR, discussed recently published research showing significant declines in computed tomography (CT) radiation dosing over the past decade.