Using weight-based protocol incorporating tube potential selection allows for lower volumes of iodinated contrast material in aortic CTA.
Image quality of aortic CT angiography (CTA) is maintained when a weight-based protocol incorporating tube potential selection is used to select lower iodine contrast volumes, according to a study published in the American Journal of Roentgenology. Researchers from the Mayo Clinic in Rochester, Minn., undertook a study to determine whether image quality was maintained with aortic CTA when performed with this protocol. The researchers evaluated results from 50 low-iodine CTA examinations, 36 internal control CTA examinations, and 50 size-matched control CTA examinations All examinations were evaluated in separate reading sessions conducted by three blinded vascular radiologists. Side-by-side unblinded comparison of the examinations was also performed. Aortic attenuation and the contrast-to-noise ratio were measured. The results showed contrast volumes were 63 percent lower when the protocol based on tube potential and patient weight was used (mean contrast volume, 49 mL for low-iodine CTA versus 133 mL for internal control CTA and 138 mL for size-matched control CTA). The mean volume CT dose index was 15.1 mGy for low-iodine CTA versus 18.8 mGy for internal control CTA, and 15.3 mGy for low-iodine CTA versus 17.1 mGy for size-matched control CTA. Of the image quality and diagnostic confidence evaluations for low-iodine CTA examinations, over 97 percent had acceptable image quality and diagnostic confidence for blinded (50/50) and unblinded (35/36) comparisons. Aortic attenuation was similar between groups. The researchers concluded that a weight-based protocol that incorporates tube potential selection allows the use of substantially lower volumes of iodinated contrast material in aortic CTA while maintaining acceptable image quality.
Study Reveals Benefits of Photon-Counting CT for Assessing Acute Pulmonary Embolism
April 23rd 2024In comparison to energy-integrating detector CT for the workup of suspected acute pulmonary embolism, the use of photon-counting detector CT reduced radiation dosing by 48 percent, according to newly published research.
The Reading Room: Racial and Ethnic Minorities, Cancer Screenings, and COVID-19
November 3rd 2020In this podcast episode, Dr. Shalom Kalnicki, from Montefiore and Albert Einstein College of Medicine, discusses the disparities minority patients face with cancer screenings and what can be done to increase access during the pandemic.
AI Adjudication Bolsters Chest CT Assessment of Lung Adenocarcinoma
April 11th 2024The inclusion of simulated adjudication for resolving discordant nodule classifications in a deep learning model for assessing lung adenocarcinoma on chest CT resulted in a 12 percent increase in sensitivity rate.