• AI
  • Molecular Imaging
  • CT
  • X-Ray
  • Ultrasound
  • MRI
  • Facility Management
  • Mammography

Can Positron Emission Mammography Have an Impact in Diagnosing Invasive Breast Cancer?

News
Article

Findings from a new pilot study showed that low-dose positron emission mammography (PEM) detected 96 percent of malignant index lesions and had a 46 percent lower false-positive rate in comparison to breast MRI.

Could low-dose positron emission mammography (PEM) provide a viable alternative in breast cancer detection?

In a prospective pilot trial, recently published in Radiology: Imaging Cancer, researchers assessed the use of low-dose PEM in 25 women (median age of 52) with newly diagnosed breast cancer. The study authors utilized different dosing of fluorine 18-labeled fluorodeoxyglucose (18F-FDG) with five patients dosed at 37 MBq, 10 patients dosed at 74 MBq and 10 patients dosed at 185 MBq, according to the study. All of the patients had concurrent magnetic resonance imaging (MRI) as well.

The researchers found that low-dose PEM diagnosed 24 out of 25 malignant index lesions, including 19 invasive cancers and five cases of in situ disease. Overall, PEM demonstrated an 87.1 percent sensitivity rate, a 94.7 percent specificity rate and a 90 percent accuracy rate, according to the study.

Can Positron Emission Mammography Have an Impact in Diagnosing Invasive Breast Cancer?

Here one can see mammography images (A and B) and a positron emission mammographic (PEM) view (C) for a 50-year female with a grade 2 invasive lobular carcinoma in the left breast. Note the 7.0 cm spiculated, irregular mass (B) and the intense uptake of fluorine 18-labeled fluorodeoxyglucose (18F-FDG) in the left breast on the PEM image. (Images courtesy of Radiology: Imaging Cancer.)

The researchers also noted the consistent detection of malignancies with PEM at the different dosing levels of 185 MBq and 74 MBq with the only missed diagnosis (a 38 mm lobular index cancer) occurring with the 37 MBq dosing.

“Although we did not observe significant differences among the various low FDG doses, most likely due to the limited sample size underpowering the study, it is noteworthy that we successfully reduced the dose to 37–185 MBq with PEM. This reduction corresponded to a decrease in radiation exposure of 0.62–0.71 mSv to 1.24–1.42 mSv. Notably, the decrement in dose did not hinder any detection of invasive disease, suggesting the plausible feasibility of utilizing lower FDG doses with this PEM device without compromising effectiveness,” wrote lead study author Vivianne Freitas, M.D., who is affiliated with the Joint Department of Medical Imaging with the University Health Network and the Sinai Health System at the Women’s College Hospital at the University of Toronto in Canada, and colleagues.

While breast MRI identified all 25 malignant index lesions, the study authors found that with additional lesion detection, PEM had a lower false positive rate (16 percent) in comparison to breast MRI (62 percent). Acknowledging the need for larger prospective trials to further explore and validate these findings, the researchers noted the potential of PEM for reducing extraneous follow-up imaging.

“These results may represent a potential added benefit of PEM, possibly decreasing both patient anxiety and the cost burden of the health care system related to additional imaging workups, including short-interval follow-ups and/or biopsy,” maintained Dr. Freitas.

(Editor’s note: For related content, see “Is Contrast-Enhanced Mammography a Viable Option for Diagnosing Invasive Lobular Carcinoma?,” “Mammography Surveillance: Can Screening DBT Have an Impact After Breast Cancer Treatment?” and “Study: Abbreviated MRI and DBT Offer Comparable Breast Cancer Detection in Dense Breasts.”)

In regard to study limitations, the researchers acknowledged that a small sample size, subjective visual parameters for lesion assessment and limiting the cohort to those who had a preoperative MRI may hamper extrapolation of these findings to a broader patient population. The study authors also suggested that awareness by radiologist readers that study participants had at least one cancer may have factored into the results.

Related Videos
Can Fiber Optic RealShape (FORS) Technology Provide a Viable Alternative to X-Rays for Aortic Procedures?
Emerging MRI and PET Research Reveals Link Between Visceral Abdominal Fat and Early Signs of Alzheimer’s Disease
Nina Kottler, MD, MS
Related Content
© 2024 MJH Life Sciences

All rights reserved.