Comparing year-long findings with and without adjunctive artificial intelligence (AI) at a breast cancer screening program in Spain, researchers found the combination of digital breast tomosynthesis and AI had a 92.5 percent accuracy for diagnosing cancer in patients with elevated risk.
The use of adjunctive artificial intelligence (AI) doubled the positive predictive value (PPV) of digital mammography (DM) exams overall and led to greater than 90 percent accuracy for DM and digital breast tomosynthesis (DBT) in detecting breast cancer in women with elevated risk, according to research findings presented recently at the European Congress of Radiology (ECR) conference in Vienna, Austria.
For the study, researchers compared the use of adjunctive AI (Transpara® version 1.7.0, ScreenPoint Medical) in 11,988 women (between the ages of 50 and 74) who had DM or DBT screening exams versus 16,555 women screened with DM or DBT the year before without AI support. In the AI group, 5,049 women had DM screening with the Hologic Selenia device and 6,949 women had DBT screening with the Hologic Selenia Dimensions device, according to the study. For the non-AI cohort, 7,229 women had DM screening and 9,326 women had DBT.
The researchers found the combination of AI and DM had an overall cancer detection rate of 8.1/1000 in comparison to 5.1/1000 for DM alone and had an accuracy rate of 95.1 percent for detecting malignancy in patients with an elevated risk for breast cancer. Adjunctive AI also doubled the overall positive predictive value (PPV) for DM (12.2 percent) in comparison to DM alone (6.1 percent), according to the study authors.
For patients with DBT and AI, the researchers reported a cancer detection rate of 9.6/1000 and a PPV of 16.5 percent in comparison to 5.8/1000 and 13.1 percent, respectively, for DBT alone. For the elevated risk group, the study authors said the combination of DBT and AI correctly diagnosed 92.5 percent of breast cancer.
“Artificial intelligence as support for readings in breast cancer screening practice increases cancer detection rate and positive predictive value for both DM and DBT,” noted Esperanza Elias Cabot, MD, who is affiliated with the Breast Cancer Unit in the Department of Radiology at the Hospital Universitario Reina Sofia in Cordoba, Spain.
(Editor’s note: For related content, see “Digital Breast Tomosynthesis and Breast Density: What a New Study Reveals” and “Medicare Mammography Study Shows Black Women Had Less Initial Access to Imaging Advances than White Women.”)
Dr. Cabot also noted a 1.7 percent decrease in the recall rate with adjunctive AI and DM (6.6 percent) in comparison to DM only 8.3 percent). She also pointed out 1.4 percent increase in the recall rate for DBT and AI (5.8 percent) in comparison to DBT alone (4.4 percent).
Of the four lesions missed by AI/DBT but detected by radiologists in the high-risk group, Dr. Cabot said two were invasive carcinomas with architectural distortion and the other two were invasive ductal carcinoma masses. Two lesions missed by AI/DM in the high-risk group included an invasive ductal carcinoma mass and a ductal carcinoma in situ with architectural distortion, according to the study.
Reference
1. Cabot EE. Artificial intelligence (AI) improves breast cancer screening performance for both digital mammography and digital breast tomosynthesis. Presented at the European Congress of Radiology, March 1-5, Vienna, Spain. Available at: https://connect.myesr.org/course/ai-in-breast-imaging-2/#1 . Accessed March 6, 2023.
Considering Breast- and Lesion-Level Assessments with Mammography AI: What New Research Reveals
June 27th 2025While there was a decline of AUC for mammography AI software from breast-level assessments to lesion-level evaluation, the authors of a new study, involving 1,200 women, found that AI offered over a seven percent higher AUC for lesion-level interpretation in comparison to unassisted expert readers.
SNMMI: Can 18F-Fluciclovine PET/CT Bolster Detection of PCa Recurrence in the Prostate Bed?
June 24th 2025In an ongoing prospective study of patients with biochemical recurrence of PCa and an initial negative PSMA PET/CT, preliminary findings revealed positive 18F-fluciclovine PET/CT scans in over 54 percent of the cohort, according to a recent poster presentation at the SNMMI conference.
Could an Emerging PET Tracer be a Game Changer for Detecting Hepatocellular Carcinoma?
June 23rd 2025In addition to over 90 percent sensitivity in detecting hepatocellular carcinoma (HCC), the glypican-3 (GPC3) targeted PET tracer 68Ga-aGPC3-scFv appeared to be advantageous in identifying HCC tumors smaller than one centimeter, according to pilot study findings presented at the SNMMI conference.