Study validates low-cost analog teleradiology

Article

German researchers have found that a technically simple low-cost teleradiology system is sufficient to provide appropriate treatment of trauma, stroke, and intracerebral hematoma patients. It could help offset the rising cost of healthcare.

German researchers have found that a technically simple low-cost teleradiology system is sufficient to provide appropriate treatment of trauma, stroke, and intracerebral hematoma patients. It could help offset the rising cost of healthcare.

A paper documenting five years of experience with the system concludes that the analog image transfer apparatus used for ordinary telephone data transmission delivers image quality adequate to triage neurotrauma patients (J Telemed Telecare 2008;14:67-70).

"In the daily practice of emergency neurosurgery, initial image quality is less important than receiving quick, reliable neurosurgical consultation," said Dr. Juergen Kreutzer of the neurosurgery department at the University of Erlangen-Nuremberg.

The quality of images transferred over the analog system was adequate to identify the location, size, and extent of pathological structures from a neurological standpoint, according to Kreutzer.

"Evaluation of gray and white matter, supratentorial edema, ventricle size, or midline shift was sufficient and reliable," he said. "Neurosurgical consulting was reliable and quick, relevant to the question of whether immediate hospital admission and further inpatient evaluation were necessary."

Kreutzer retrospectively analyzed 1024 neurosurgical cases between 1995 and 2000 involving the relatively unsophisticated analog image transfer system (CP220, Vetter-Vaillinger, Ostfildern-Nelligen, Germany). It was used to transmit CT and MR scans from the emergency departments of seven small hospitals located in southern Germany to a regional neurosurgical center.

The study found that in 67% of the cases, patient ground transportation and subsequent hospital admission were not necessary, saving the healthcare system over $535,000. Equipment purchase price of the image transfer system was $16,800 per hospital.

"Without a teleradiology system, smaller hospitals are virtually forced to arrange expensive transportation to the nearest neurosurgical center," Kreutzer said.

None of the seven affiliated hospitals had a neurosurgical consultant on call, and most did not have a radiologist on call.

The problem with more expensive DICOM teleradiology systems is they require hardware in every connected peripheral hospital, Kreutzer said. Such systems offer high-quality image transfer but require frequent technical servicing, presenting compatibility issues and judicial concerns over patient confidentiality.

Data transmission speed over the analog system was acceptable in its design context. Transmission of one image over the 19,200-baud telephone network took approximately 20 seconds. Receiving a complete cranial scan was possible in three to four minutes, he said.

Related Videos
Improving the Quality of Breast MRI Acquisition and Processing
Can Fiber Optic RealShape (FORS) Technology Provide a Viable Alternative to X-Rays for Aortic Procedures?
Does Initial CCTA Provide the Best Assessment of Stable Chest Pain?
Making the Case for Intravascular Ultrasound Use in Peripheral Vascular Interventions
Can Diffusion Microstructural Imaging Provide Insights into Long Covid Beyond Conventional MRI?
Assessing the Impact of Radiology Workforce Shortages in Rural Communities
Emerging MRI and PET Research Reveals Link Between Visceral Abdominal Fat and Early Signs of Alzheimer’s Disease
Reimbursement Challenges in Radiology: An Interview with Richard Heller, MD
Nina Kottler, MD, MS
The Executive Order on AI: Promising Development for Radiology or ‘HIPAA for AI’?
Related Content
© 2024 MJH Life Sciences

All rights reserved.