Magnetic resonance imaging’s accuracy in detecting cancer in the lymph nodes of newly diagnosed breast cancer patients is nothing to sniff at – 80 percent with diffusion-weighted MRI and 85 percent with axial T1-weighted MRI, Canadian researchers have reported. But it’s not quite high enough to skip a lymph node dissection, according to a study published online Dec. 5 in the journal Radiology.
Magnetic resonance imaging’s accuracy in detecting cancer in the lymph nodes of newly diagnosed breast cancer patients is nothing to sniff at – 80 percent with diffusion-weighted MRI and 85 percent with axial T1-weighted MRI, Canadian researchers have reported. But it’s not quite high enough to skip a lymph node dissection, according to a study published online Dec. 5 in the journal Radiology.
University of Toronto researchers chose 61 women (average age 53) with invasive breast cancer to undergo preoperative breast MRI. Axial T1-weighted MRI without fat saturation and diffusion-weighted (DW) MR images were analyzed by two experienced radiologists uninformed of the pathology findings.
They found the sensitivity, specificity, and accuracy to be 88 percent, 82 percent, and 85 percent, respectively, for axial T1-weighted MR imaging and 84 percent, 77 percent, and 80 percent for diffusion-weighted (DW) imaging. Apparent diffusion coefficients (ADCs) were significantly lower in the malignant group.
The team concluded that unenhanced MRI techniques showed high accuracy in the preoperative evaluation of patients with invasive breast cancer, and that, while the results indicated reliable and reproducible assessment with DW imaging, “it is unlikely to be useful in clinical practice.”
Could Virtual Non-Contrast Images from Photon-Counting CT Reduce Radiation Dosing with CCTA?
March 28th 2024Emerging research on coronary artery calcium scoring for the assessment of coronary artery disease (CAD) suggests the use of virtual non-contrast images from photon-counting CT may lead to a nearly 20 percent reduction in radiation dosing.
FDA Clears CT-Based AI Tools for PE Detection and Stroke Severity Assessment
March 26th 2024The artificial intelligence (AI) modalities CINA-iPE and CINA-ASPECTS may facilitate improved detection of incidental pulmonary embolism and stroke evaluation, respectively, based on computed tomography (CT) scans.