Whether it scans in four slices or 16, CT is the method of choice for detecting pulmonary emboli, researchers said Thursday. Even four-slice technology boasts a negative predictive value greater than 99%, better than ventilation/perfusion (V/Q) studies or conventional pulmonary angiography.
Whether it scans in four slices or 16, CT is the method of choice for detecting pulmonary emboli, researchers said Thursday. Even four-slice technology boasts a negative predictive value greater than 99%, better than ventilation/perfusion (V/Q) studies or conventional pulmonary angiography.
Differences among four-, eight-, and 16-slice scanners appear marginal so far, but few data are available to solidify any claims of superiority for 16, except in the speed department. Researchers at Stanford University clocked lung scan times at 26.6 seconds for four-slice, 9.25 seconds for eight-slice, and 5.45 seconds for 16.
Dr. Alessandro Napoli and colleagues at Stanford reviewed CT studies for 1240 consecutive patients referred for suspected pulmonary emboli. Overall, 20% of cases were deemed positive, with 41% of emboli found in the segmental arteries, 27% in lobal regions, 17% in subsegmental arteries, and 15% on the main branches.
While there was no statistically significant difference in detection rates among the three generations of scanners, readers said eight- and 16-slice studies yielded more and clearer diagnostic data. The 16-slice scanner may eventually prove better at finding subsegmental emboli, but only a small number of cases were included in the study.
If a CT study is negative, meanwhile, it is safe to forgo further examination. Researchers at the University of South Carolina conducted a metastudy of 14 published papers with 3283 patients who had undergone CTA to evaluate suspected pulmonary emboli, had negative findings, and stopped anticoagulation therapy based on those findings. Fourteen developed fatal pulmonary embolism, 23 demonstrated nonfatal embolism, and 52 showed evidence of deep venous thrombosis during follow-up.
The studies produced 95% to 100% negative predictive value (NPV), with an average of 99.1%. NPV for mortality clocked in at 99.4%. Whether the CTAs were performed on single-slice or multislice CT made no significant difference. By comparison, conventional pulmonary angiography has an NPV of 98.4%, and V/Q studies average 88%.
Can MRI-Based AI Bolster Biopsy Decision-Making in PI-RADS 3 Cases?
December 9th 2024In patients with PI-RADS 3 lesion assessments, the combination of AI and prostate-specific antigen density (PSAD) level achieved a 78 percent sensitivity and 93 percent negative predictive value for clinically significant prostate cancer (csPCa), according to research presented at the Radiological Society of North American (RSNA) conference.
The Reading Room: Artificial Intelligence: What RSNA 2020 Offered, and What 2021 Could Bring
December 5th 2020Nina Kottler, M.D., chief medical officer of AI at Radiology Partners, discusses, during RSNA 2020, what new developments the annual meeting provided about these technologies, sessions to access, and what to expect in the coming year.
RSNA 2020: Addressing Healthcare Disparities and Access to Care
December 4th 2020Rich Heller, M.D., with Radiology Partners, and Lucy Spalluto, M.D., with Vanderbilt University School of Medicine, discuss the highlights of their RSNA 2020 session on health disparities, focusing on the underlying factors and challenges radiologists face to providing greater access to care.
New Interventional Radiology Research Shows Merits of Genicular Artery Embolization for Knee OA
December 3rd 2024In a cohort of over 160 patients with knee osteoarthritis (OA), including grade 4 in nearly half of the cases, genicular artery embolization led to an 87 percent improvement in the quality of life index, according to research presented at the
Siemens Healthineers Debuts New Photon-Counting CT Systems at RSNA
December 2nd 2024Debuting at the Radiological Society of North American (RSNA) conference, the new photon-counting computed tomography (PPCT) scanners Naeotom Alpha.Pro and Naeotom Alpha.Prime reportedly combine rapid scan times with high-resolution precision.